DE eng

Search in the Catalogues and Directories

Page: 1 2
Hits 1 – 20 of 26

1
The effect of presentation level and stimulation rate on speech perception and modulation detection for cochlear implant users
Brochier, Tim; McDermott, Hugh J.; McKay, Colette M.. - : Acoustical Society of America, 2017
BASE
Show details
2
Influence of contralateral acoustic hearing on adult bimodal outcomes after cochlear implantation
Plant, Kerrie; van Hoesel, Richard; McDermott, Hugh. - : Taylor & Francis, 2016
BASE
Show details
3
Factors predicting postoperative unilateral and bilateral speech recognition in adult cochlear implant recipients with acoustic hearing
Plant, Kerrie; McDermott, Hugh; van Hoesel, Richard. - : Lippincott Williams & Wilkins, 2016
BASE
Show details
4
Clinical outcomes for adult cochlear implant recipients experiencing loss of usable acoustic hearing in the implanted ear
Plant, Kerrie L; van Hoesel, Richard J. M; McDermott, Hugh J. - : Lippincott Williams & Wilkins, 2015
BASE
Show details
5
Speech Perception and Localisation with SCORE Bimodal: A Loudness Normalisation Strategy for Combined Cochlear Implant and Hearing Aid Stimulation
Francart, Tom; McDermott, Hugh. - : Public Library of Science, 2012
Abstract: A significant fraction of newly implanted cochlear implant recipients use a hearing aid in their non-implanted ear. SCORE bimodal is a sound processing strategy developed for this configuration, aimed at normalising loudness perception and improving binaural loudness balance. Speech perception performance in quiet and noise and sound localisation ability of six bimodal listeners were measured with and without application of SCORE. Speech perception in quiet was measured either with only acoustic, only electric, or bimodal stimulation, at soft and normal conversational levels. For speech in quiet there was a significant improvement with application of SCORE. Speech perception in noise was measured for either steady-state noise, fluctuating noise, or a competing talker, at conversational levels with bimodal stimulation. For speech in noise there was no significant effect of application of SCORE. Modelling of interaural loudness differences in a long-term-average-speech-spectrum-weighted click train indicated that left-right discrimination of sound sources can improve with application of SCORE. As SCORE was found to leave speech perception unaffected or to improve it, it seems suitable for implementation in clinical devices.
Keyword: Research Article
URL: https://doi.org/10.1371/journal.pone.0045385
http://www.ncbi.nlm.nih.gov/pubmed/23115622
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3480354
BASE
Hide details
6
A fundamental frequency estimator for the real-time processing of musical sounds for cochlear implants
In: Speech communication. - Amsterdam [u.a.] : Elsevier 49 (2007) 2, 113-122
BLLDB
OLC Linguistik
Show details
7
Speech perception with a cochlear implant sound processor incorporating loudness models
In: Acoustics research letters online. - Melville, NY : ASA 6 (2005) 1, 7-13
BLLDB
Show details
8
Improvements in speech perception with an experimental nonlinear frequency-compression hearing device.
In: International Journal of Audiology, 44(5): 281-292 (2005)
BASE
Show details
9
The relationship between speech perception and electrode discrimination in cochlear implantees
In: Acoustical Society of America. The journal of the Acoustical Society of America. - Melville, NY : AIP 108 (2000) 3,1, 1269-1280
BLLDB
Show details
10
The relationship between speech perception and electrode discrimination in cochlear implantees
BASE
Show details
11
Improvements in speech perception with use of the AVR TranSonic frequency-transposing hearing aid
In: Journal of speech, language, and hearing research. - Rockville, Md. : American Speech-Language-Hearing Association 42 (1999) 6, 1323-1335
BLLDB
Show details
12
Hearing - Articles and Reports - Improvements in Speech Perception With Use of the AVR TranSonic Frequency-Transposing Hearing Aid
In: Journal of speech, language, and hearing research. - Rockville, Md. : American Speech-Language-Hearing Association 42 (1999) 6, 1323-1335
OLC Linguistik
Show details
13
A frequency importance function for a new monosyllabic word test
BASE
Show details
14
Speech cues for cochlear implantees: spectral discrimination [Abstract]
BASE
Show details
15
Speech cues for cochlear implantees: spectral discrimination
BASE
Show details
16
The perception of temporal patterns for electrical stimulation presented at one or two intracochlear sites
In: Acoustical Society of America. The journal of the Acoustical Society of America. - Melville, NY : AIP 100 (1996) 2,1, 1081-1092
BLLDB
Show details
17
The perceptual dimensions of single-electrode and nonsimultaneous dual-electrode stimuli in cochlear implantees
In: Acoustical Society of America. The journal of the Acoustical Society of America. - Melville, NY : AIP 99 (1996) 2, 1079-1090
BLLDB
Show details
18
The importance of different frequency bands to the speech perception of cochlear implantees [Abstract]
BASE
Show details
19
The spectral maxima sound processor: recent findings in speech perception and psychophysics
BASE
Show details
20
Signal processing for multichannel cochlear implants: past, present and future [Abstract]
BASE
Show details

Page: 1 2

Catalogues
0
0
2
0
0
0
0
Bibliographies
6
0
0
0
0
0
0
0
0
Linked Open Data catalogues
0
Online resources
0
0
0
0
Open access documents
19
0
0
0
0
© 2013 - 2024 Lin|gu|is|tik | Imprint | Privacy Policy | Datenschutzeinstellungen ändern